Soleus Air Mac 7500 User Manual

PORTABLE AIR CONDITIONER  
MAC 7500 Owner’s Manual  
• Air Conditioner  
• Dehumidifier  
• Oscillating Fan  
Please read this owner’s manual  
POWERED BY  
carefully before operating the unit.  
66126113.p65  
17  
02-12-21, 15:44  
• Unplug unit from the electrical outlet when not in use and  
before cleaning it.  
• Do not use an adapter plug extension cord.  
• Do not use near gas appliances, open flames (fireplaces) or  
near the vicinity flammable liquids.  
• Do not operate this unit if it had a damaged cord or plug or if  
it is not warking properly, or has been dropped or damaged  
in any manner. Take the unit to the nearest authorized. Ser-  
vice Facility for examination, repair or electrical/mechanical  
adjustment.  
• The use of accessories and attachments not recommended  
or sold by  
injury.  
may cause fire, electric shock or  
To protect against risk of electrical shock, do not immerse  
the unit, cord or plug in water or any other liquid.  
• Do not cut or remove the third (ground) prong from the power  
cord.  
• If the plug gets hot, call a qualified electrician.  
• Close supervision is required when the unit is used by or near  
children.  
• Do not stick anything into the air outlet of the air conditioner.  
• Do not use in a room with poor air circulation.  
• Do not expose the unit to direct sunlight.  
• Do not use the unit near water.  
2
66126113.p65  
2
02-12-21, 15:44  
PACKAGE CONTAINS:  
Mobile Air Conditioner  
Air Exhaust Duct  
LITHIUM BATTERY 3V –  
Window Kit - 3 Sliding Panels  
Window Kit Fastener Screws (4)  
User Manual  
Exhaust Duct Window Kit Adapter  
Romote Controller  
NAMES OF PARTS  
FRONT  
control panel  
air flow guider  
swing louver  
handle  
front air outlet grill  
water tank  
cable(power  
cord and plug)  
castol  
BACK  
upper air  
inlet grill  
Outlet for Continuous Drainage  
Use exclusively for continuous  
drainage.  
Don't pull out the outlet except  
for this application.Otherwise  
the drain will leak.  
hot air outlet grill  
lower air inlet grill  
3
66126113.p65  
3
02-12-21, 15:44  
Exhaust Duct  
Exhaust Duct  
Unit Terminal End  
Window Kit Adaptor  
Window Kits  
Exhaust Duct  
When you use the unit as an air conditioner, the hot exhaust air must be directed out of the  
room. The exhaust duct is used to allow the hot air out. DO NOT INSTALL OR USE THE  
EXHAUST DUCT WHEN THE UNIT IS OPERATED AS A DEHUMIDIFIER OR FAN.  
a) Slide exhaust connector all the  
over the hot Air outlet grill.  
b) Mount the external and of the ex-  
haust duct onto a bole of 5 1/ " (132  
4
mm) on the wall for optional wall  
hot air outlet installation.  
4
66126113.p65  
4
02-12-21, 15:44  
c) Or connect the window kit adaptor to the external end of the exhaust duct for a window  
or sliding door hot air outlet installation.  
NOTE: In order to increase the efficiency, the exhaust duct should be keep as short and  
straight as possible. The exhaust hose can be cut shorter by unthreading either end of the  
exhaust duct counter clockwise. It is not recommended to increase the manufacturer’s length  
of the exhaust hose. This may impede or damage the unit.  
Window Kit Installation  
a) Open window or sliding door for approximately 5 inches (130 mm).  
b) Adjust the length of the window kit to the same length of the window or the sliding door.  
Use all three panels if necessary.  
c) Use screws to affix the window kit length.  
d) Place the window kit to the window or sliding door. Close the window or door as far as  
it goes.  
e) Mount the window kit extension of the exhaust host onto the window kit.  
f) Use screws on the window kit extension if necessary.  
NOTE: When using the window kit on a window or sliding door it will cause the window or  
sliding door not to be properly closed and locked. Additional security measurements should be  
taken.  
windows  
exhaust air opening  
5
66126113.p65  
5
02-12-21, 15:44  
CONTROL PANEL  
REMOTE CONTROLLER  
6
66126113.p65  
6
02-12-21, 15:44  
OPERATION USING CONTROL PANEL  
1)  
For Manual Mode:  
Press the Mode Button  
a) Cool - Cooling function on indicator.  
b) Dry - Dehumidify function on indicator.  
c)  
Fan - Fan on indicator.  
2)  
For Cooling Operation:  
a) Be sure that the drain tank is properly placed in the unit.  
b) Install the exhaust duct properly.  
c)  
Plug the Power Cord to the power outlet.  
d) Press the Mode Button until the cool indicator is on.  
NOTE: During hot days, the unit will cool off the room most efficiently by setting the fan at the  
lowest speed. Reducing the length of the exhaust duct, insulating the exhaust duct and keeping  
direct sunlight to a minimurn will also improve the cooling efficiency.  
3)  
Dehumidifying Operation:  
a) Be sure that the drain tank is properly placed in the unit.  
b) Plug the Power Cord to the power outlet  
c)  
Turn on the unit by pressing the ON/OFF Button on the control panel.  
d) Press the Mode Button until the DRY indicator is on.  
NOTE: Do not use the exhaust duct when the unit is running at dehumidisying mode. You must  
remove the exhaust duct from the unit. When the unit is running at dehumidifying mode, the fan  
speed cannot be adjusted.  
Keep the windows and the doors closed to aid the effectiyeness of the unit in removing the  
moisture from the room.  
7
66126113.p65  
7
02-12-21, 15:44  
4)  
Fan Operation:  
a) Plug the Power Cord to the power outlet.  
b) Turn on the unit by pressing the ON/OFF Button on the control panel.  
c)  
Press the Mode Button until ‘FAN’ indicator is on.  
d) Select the fan speed by pressing the Fan Speed Button.  
NOTE: When the unit is running on fan mode, the exhaust duct is inoperative and is not  
required.  
OPERATION USING REMOTE CONTROLLER  
The remote controller provided with the unit may operate this portable air conditioner. The  
remote controller uses one LITHIUM BATTERY 3V . Install the battery before using the re-  
mote controller.  
1. Press the On/Off key to turn on the unit.  
2. Press Mode Key to:  
a) Cool indicator is on = Cooling Function  
b) Dry indicator is on = Dehumidify Function  
c)  
3. Fan Speed:  
a) Press the Fan Speed key to turn fan speed to high or low.  
4. Swing:  
a) Press swing key to turn on auto swing function.  
Fan indicator is on = Fan Function  
Do not dispose of batteries in fire, batteries may  
explode or leak.  
8
66126113.p65  
8
02-12-21, 15:44  
CONDENSATE WATER DRAINAGE  
1)  
Internal Water Tank  
When operating in cooling or dehumidifying mode, the condensate water will drain into  
the internal water tank. Depending on the surrounding humidity, the unit can continu-  
ously operate for 2 to 12 hours before the internal water tank is full. When the internal  
water tank gets full, a beep slarm will sound eight times for 15 seconds. The compres-  
sor stops running and the fan will continue to run in the set speed for three minutes  
before the entire unit automatically shuts off.  
When the water tank is full, take out the entire water tank slowly and discard the water  
inside the tank, place it back to its original position. You will then be able to turn on the  
unit again.  
If you want to take out the internal tank before it is full of water, please stop the unit  
first. Wait for 3 minutes before taking out the water tank to prevent the condensate  
water from discharging into the unit.  
NOTE: Do not take out the water tank when the unit is running on either cooling or dehumidi-  
fying mode or the alarm will sound and the compressor stops. The mode will automatically  
change to FAN mode and the compressor will require approximately 3 minutes to restart to the  
cooling/dehumidifying cycle.  
9
66126113.p65  
9
02-12-21, 15:44  
Do not remove the water tank when the unit is in use.  
Always turn “Off” the unit before removing water tank.  
Periodically inspect and clean the drain valve to prevent  
clogging.  
METHOD OF CONTINUOUS DRAINAGE:  
1. Slide out drain valve from the left side of the unit.  
2. Connect a rubber pipe to the valve (not included).  
3. Make sure the rubber pipe drains downward.  
10  
66126113.p65  
10  
02-12-21, 15:44  
AIR FILTER  
• Soleus Air recommends cleaning your air filter at least after every two weeks of use. Keep-  
ing your air filter clean will maximize the performance and life of this product.  
• Open the air filter cover on the left side of the unit (fig. a)  
• Remove the filter from the cover.  
• Wash the filter using warm water and a mild dishwasher detergent.  
• Allow to air dry before replacing in unit.  
Fig. a  
Water Tank  
• Using the handle, slowly remove water tonk from unit (fig. b).  
• Pour out any condensation accumulated in water tank (fig. c)  
• Wash water tank using warm water and a mild dishwasher detergenr.  
• Allow to dry completely.  
• Replace water tank in unit (fig. d).  
Fig. d  
Fig. c  
Fig. b  
11  
66126113.p65  
11  
02-12-21, 15:44  
NOTE: Be very careful when using an external water tank. The unit will not shut off automati-  
cally when an external water tank is full. Spill water can cause substantial damages to carpet,  
furniture and other valuables.  
Do not use lengthy drainage tabing without a condensate water pump.  
MAINTENANCE  
NOTE: Make sure power is off and the plug is pulled out of the power outlet before performing  
any maintenance activities.  
1)  
2)  
Case  
a) Keep the unit from being exposed directly to the sun for possible color fading.  
b) Clean the surface with a damp cloth and dry it with a soft towel.  
Storing the Unit for an Extended Period of Time  
a) Ensure that the water drain tank is empty.  
Remove the stopper from the water drain pipe and allow draining until empty.  
(Fig. e)  
b) The water drain valve should be reinserted back in the unit.  
c)  
The filter should be cleaned and air dried.  
d) The power cable must be disconnected from power outlet and neatly rolled.  
(Fig. f)  
e) The unit should be stored in a dry place.  
Fig. f  
Fig. e  
12  
66126113.p65  
12  
02-12-21, 15:44  
TROUBLE SHOOTING  
PROBLEM  
POSSIBLE CAUSE  
REMEDY  
Unit does not operate  
Unit is umplugged  
Secorely plug receptacle into the power  
outlet  
Drain tank is full  
Empty water tank  
Water tank not installed correctly  
Completely insert water tank  
Clear exhaust hose  
Air exhaust is clogged  
Unit does not cool  
room  
There is a heating source in the room  
Turn down or off the other heating  
source  
Air filter is dirty  
Clean or replace the air filter  
Air exhaust is not installed correctly  
Check the air exhaust duct to make sure  
that the hot exhaust air is let out of the  
room freely  
Room is too big or too much amblent  
sunlight is reaching in  
This unit provides spot cooling or cool-  
ing for a room no larger than 150  
square feel with standard ceilling height  
71/ "  
2
There is frost on the evaporator  
There is frost on the evaporator  
Surface is not level  
The unit will defrost automatically and  
return to operation afterwards  
In dehumidifying mode,  
no cool air coming out  
The unit will defrost automatically and  
will return to operation afterwards  
Noise or vibration  
Place unit on a level surface and away  
from obstructions  
Surface is not level  
Place unit on a level surface away from  
obstructions  
Drainage pipe is loose  
Unit has been moved  
When moving unit, empty drain tank first  
and keep unit upright at all times  
Stopper on water drain pipe is loose  
Make sure the stopper on the water  
drain pipe is securely in place  
Machino stops and  
starts  
Air exhaust is not attached proparty  
Air exhaust is curved too much  
Check installation of air exhaust hose  
Try to keep the air exhaust horizontal  
13  
66126113.p65  
13  
02-12-21, 15:44  
SPECIFICATIONS  
Model #  
MAC - 7500  
~
Power Source  
115V / 60Hz  
Cooling capacity  
7500 BTU/h  
Dehumidifyling capacity  
Cooling input power  
Rated current  
24.0 liters/day  
1000W  
8.7A  
Refrigerant type  
HCFC R22  
Refrigerant capacity  
Operating Range - Cooling  
(indoor air temperature)  
Unit dimensions (H x D x W)  
1.15 lb  
Max 95°F Dry Bulb - 71°F Wet Bulb  
Min 67°F Dry Bulb - 57°F Wet Bulb  
31" x 12.8" x 16.3"  
Specifications are subject to change without notice  
PRODUCT INFORMATION  
If you have problems or questions concerning your air conditioner, you will need the following  
information. Model and Serial numbers are on the nameplate on the back of the unit.  
Model No.  
Serial No.  
Date of Purchase  
Dealer’s Name  
Purchaser’s Name  
Day Phone  
Dealers Address  
Evening Phone  
14  
66126113.p65  
14  
02-12-21, 15:44  
DISCLAIMER  
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS  
USER’S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER SOLEUS  
INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TESTS FOR THE INFORMA-  
TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.  
CONTACT INFORMATION  
For Optional and Spare Parts  
Technical Support  
Warranty Claim  
Customer Service  
Please Call (888) 8-Soleus  
Or Write to:  
Soleus International Inc.  
9451 Telstar Ave.  
El Monte CA 91731 USA  
15  
66126113.p65  
15  
02-12-21, 15:44  

Murphy Iguard Al 02058b User Manual
Panasonic Cs A7ckp User Manual
Panasonic Cu Xe12eke User Manual
Sanyo 18kls52 User Manual
Schneider Electric Duradrive Direct Coupled Actuators Ma4x 707x User Manual
Sharp Af R80fx User Manual
Sharp Replacement Filter Fzc100hfu User Manual
Studer Innotec Hpc5048 User Manual
Toshiba Air Conditioner Ceiling Type User Manual
Vtech Ls6426 4 User Manual